IV Administration Set - With Universal Spike and Spin-Lock Connector

IV Administration Set - With Universal Spike and Spin-Lock Connector

SKU:

14 in stock

Regular price $4.89 CAD
Regular price Sale price $4.89 CAD
Sale Sold out
Shipping calculated at checkout.
Size

We have 3 Options: 79in, 84in, and 85in

Option#1: B-Series Set, v1402

Length: 79in, 201cm

REF: V1402 | GTIN: 04046964188183

Instructions on Package:

Use Aseptic Technique

Replace set as per CDC Guidelines

1. Close roller clamp. Fully spike container. Hang fluid container. Gently squeeze and release drip chamber until approximately half full. 

NOTE: Vent cap should remain in the closed position unless infusing from a solid stopper glass bottle.

2. Prime set by slowing opening roller clamp and allow fluid to fill tubing. Close roller clamp. Ensure air is expelled. Repeat prime if necessary. Attach infusion Device.

3. Slowly open roller clamp and adjust for desired flow rate.

-

Option#2: v1421-20, 84in

Length: 84in, 213cm

REF: V1421-20 | GTIN: 04046964188244

Instructions on Package:

Use Aseptic Technique

 

To access Injection site: Swab injection site vigorously for 15 seconds and allow to air dry prior to use. Add compatible medication by injecting through injection site.

Replace set as per CDC Guidelines.

1. Close roller clamp. Fully spike container. Hang fluid container. Gently squeeze and release drip chamber until approximately half full. 

NOTE: Vent cap should remain in the closed position unless infusing from a solid stopper glass bottle.

2. Prime set by slowing opening roller clamp and allow fluid to fill tubing. Close roller clamp. Ensure air is expelled. Repeat prime if necessary. Attach infusion Device.

3. Slowly open roller clamp and adjust for desired flow rate.

-

Option#3: 352601, v1501, 85in

Length: 85in, 216cm

REF: v1501, 352601 | GTIN: 04046964181795

Instructions on Package:

Use Aseptic Technique

Replace set as per CDC Guidelines.

1. Close roller clamp. Fully spike container. Hang fluid container. Gently squeeze and release drip chamber until approximately 1/3 full. 

NOTE: Vent cap should remain in the closed position unless infusing from a solid stopper glass bottle.

2. Prime set by slowing opening roller clamp and allow fluid to fill tubing. Close roller clamp. Ensure air is expelled. Repeat prime if necessary. 

-

For Gravity Administration

3. Attach to infusion device.

4. Slowly open roller clamp and adjust for desired flow rate.

For Use with VISTA basic pump

Cautions:

Do not use same tubing section in pump for more than 24 hours.

Unrestricted fluid flow may occur if the set is not properly installed in the pump.

Set does not contain set based free flow protection.

Refer to VISTA basic Instructions for use.

1. Proceed with steps 1&2 in prior section.

2. Open the door of the pump. Push and hold open the clamp at the top of the fluid path. Insert tubing in clamp and release clamp.

3. Thread the tubing down the fluid path making sure the tubing is pressed into the Air-in-Line Detector at the bottom of the fluid path.

4. Close the door of the pump.

5. Open all clamps on the tubing. Check that no drops are falling into the drip chamber. Attach infusion device.

6. Proceed with pump operating device.